IntellaNet™ by MCE
Technologically advanced, cost effective controller for mid-rise and high-rise traction applications
IntellaNet by MCE is an advanced controller providing an unmatched combination of performance and lower life cycle costs. IntellaNet is an ideal solution for geared and gearless applications serving up to 64 floors and accommodating up to 9 car groups. IntellaNet SCR supports 1,600 feet per minute DC performance while delivering a smooth, comfortable ride.
Lower life cycle costs and high performance: The IntellaNet design philosophy maximizes performance and efficiency. The result is a controller that incorporates a decentralized network design and provides lower overall cost throughout product life.
Cost efficiency begins at installation: IntellaNet is faster and more efficient to install than most controllers. For example, traveler cable material and labor costs are reduced since there are
typically fewer than 25 wires from car to machine room. Efficiency continues over the life of the
product with lower ongoing maintenance and adjustment costs. Typical adjustment time is less
than 8 hours, call backs and change orders are few, and the "building block" design philosophy
means fewer parts to inventory. IntellaNet's energy conservation mode, operating during off-peak
hours, decreases equipment wear and tear and saves energy without sacrificing performance
when it is needed.
IntellaNet's digitally controlled closed-loop speed-and distancebased velocity feedback system ensures a smooth, comfortable ride. Multiple microprocessors provide a higher level of reliability and facilitate future system improvement and expansion. IntellaNet's LonWorks-based, modified ETA dispatching system is user programmable. Redundant traffic management and AI (artificial intelligence) dispatching are optional. Cross Registration or Cross Cancellation provides legacy system compatibility during modernization projects.
Field programmability easily handles changing occupancy needs and management requirements. More than 400 programmable options allow you to customize the system on site.

IntellaNet specifications
Maximum
car speed |
700 fpm
3.56 mps |
1,600 fpm
8.12 mps |
1,600 fpm
8.12 mps |
Landings/
group size |
64 openings/Simplex or up to 9-car group |
Landing
systems |
Perforated tape/magnets |
| Drive type |
AC flux vector |
DC six-pulse |
Ward Leonard |
Harmonic
distortion |
Industry standard |
Industry standard |
N/A |
| Motor control |
Closed-loop velocity feedback |
| Dispatching |
LON-based dispatching with modified ETA system |
| Monitoring |
Lift-Net universal monitoring system |
Security
options |
Access control for elevators, keyboard control for elevators |
Field
connections |
Serial communication, conventional wiring or a combination of both |
| Choke/filter |
Included inside cabinet |
Included outside cabinet |
N/A |
| Environment |
32-113°F, 0-45°C, relative humidity non-condensing up to 95% |
Standard
enclosure |
40" w x 72" h x 20" d
Enclosure size may vary per specific application |
|
|
| |
 |
Advantages
- Reduced installation labor cost
- Networked serial communication for cartop or machine room programmability
- Comprehensive on-board system diagnostics
- Remote diagnostics minimize downtime
- Sophisticated dispatching significantly reduces passenger waiting time
- Standard "building block" design philosophy means fewer parts to inventory
Applications
- Modernization or new construction
- Mid-rise to high-rise
- Geared or gearless
- Simplex
- Groups to 9 cars and 64 openings
- 1,600 fpm, 8.12 mps (DC)
- 700 fpm, 3.56 mps (AC)
Benefits
- Non-proprietary
- Field programmable
- Field proven performance
- Modular design
- Lifetime technical support
Features/options
- Monitoring screen displays all inputs and outputs in real time
- Diagnostic screens display the last fifty events in plain English
- Two-wire hookup to peripheral equipment
- Unique pre-wired cartop and car station
IntellaNet features
- Inspection service
- Independent service
- Attendant service
- Pretorque capability
- Car diagnostic screen
- Dispatcher diagnostic screen
- Car scope screen
- Earthquake mode
- Shuttle operation
- Dual lobby service
- Split group lobby service
- Emergency power (group)
- CE voice annunciation
- Software security locks
- Holiday service
IntellaNet optional features
- Energy conservation mode
- Security access (car button access)
- Redundant dispatching
- ETSL (Emergency Terminal Speed Limiting)
- Rope gripper interface
- Emergency power (inter group)
- Medical emergency
(phase 1 and 2)
- Seismic sensors
- Counter weight displacement kit
Code compliance
- ANSI/ASME A17.1a -2002, A17.5, CAN/CSA B44,
B44.1, NEC, CEC
|
|
 |
|